Welcome to visit H&T Optoelectronic Co.,Ltd. Tel:86-755-86197637,008613922888473
 
产品分类
Products search
Keyword
Search
Din-rail Power Supply
75W industrial Din-Rail Switching Power Supply
Low price and high reliability
105Celsius degree output capacitor
Universal AC input
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With short-circuit and overload protection
Compact size,light weight
100% full-load burn-in test
Install with EMI filter,minimum wave
  • Description
  • Parameter
  • Application
  • Download
  • Related


12V 6.3A, 24V 3.2A, 48V 1.6A Industrial Din-Rail Switching Power supply


Model

DR-75-12

DR-75-24

DR-75-48

Output

12V 0-6.3A

24V 0-3.2A

48V 0-1.6A

Error

+-2%

+-1%

+-1%

Output power

75.6W

76.8W

76.8W

Ripple & Noise (ma*.)

100mVp-p

150mVp-p

240mVp-p

Efficiency

76%

80%

81%

AC input voltage range

85~264VAC  47~63HZ    120~370VDC

Input current

1.8A/115V 0.9A/230V

AC Inrush current

Cold-start current 30A/115V 60A/230V

Leakage current

<3.5mA/240VAC

DC adjustable range

+-10% rated output voltage

Overload protection

105%-150% cut off the output, auto-recovery

Over-voltage protection

121%-142% cut off the output, auto-recovery

Setup, rise, hold time

1000ms,60ms,50ms

Withstand voltage

I/P-O/P:3KvAC I/P-FG:1.5KvAC O/P-FG:0.5KVAC

Isolation resistance

Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MOhms

Working temperature and humidity

-10 degree ~+50 degree     20%~90%RH

Temp. coefficient

+-0.03%/ degree  (0 ~ 50 degree )

Overall dimension

55.5*125.2*100mm  (W*H*D)

Weight

0.6kgS

Note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 degree  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives.