Welcome to visit H&T Optoelectronic Co.,Ltd. Tel:86-755-86197637,008613922888473
 
产品分类
Products search
Keyword
Search
Din-rail Power Supply
Industrial DIN Rail Power Supply 120W
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
isolation class 2
LED indicator for power on
100% full load burn-in test
2 year warranty
  • Description
  • Parameter
  • Application
  • Download
  • Related


SPECIFICATIONS
OUTPUT
Model HT-DR-120-12 HT-DR-120-24 HT-DR-120-48
DC Voltage 12V 24V 48V
Rated Current 10A 5A 2.5A
Current Range 0-10A 0-5A 0-2.5A
Rated Power 120W 120W 120W
Ripple & Noise 80mVp-p 80mVp-p 100mVp-p
Voltage Adj. Range 12-14V 24-28V 48-53V
Voltage Tolerance ±2% ±1% ±1%
Line regulation ±0.5% ±0.5% ±0.5%
Load regulation ±1% ±1% ±1%
Setup, Rise Time 500ms,70ms/230VAC   500ms,70ms/115VAC at full load
Hold Up Time 36ms/230VAC   32ms/115VAC at full load
INPUT
Voltage Range 88~132VAC/176~264VAC selected by switch   47~63Hz; 248~370VDC
AC Current 2.6A/115VAC   1.6A/230VAC
Efficiency 80% 84% 85%
Inrush Current Cold start 20A/115V   40A/230V
Leakage Current <3.5mA/240VAC
PROTECTION
Over Load 105%~150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 15-16.5V 29-33V 58-65V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. 85℃±5℃(TSW1) 90℃±5℃(TSW1) 90℃±5℃(TSW1)
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
Working Temp., Humidity -10℃~+60℃; 20%~90% RH non-condensing
Storage Temp., Humidity -20℃~+85℃; 10%~95%RH
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC/25℃/70%RH
STANDARD
Safety Standard Design refer to UL508,UL60950-1,TUV EN60950-1
EMC Standard Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2(EN50082-2), heavy industry level, criteria A
OTHERS
Dimension 65.5*125.2*100mm(L*W*H)
Weight 0.79Kg
Packing 20pcs/carton/16.5kg/1.29CUFT
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.

12V 10A, 24V 5A, 48V 2.5A Din-Rail Industrial Switching Power Adaptor

Correct usage of Din-Rail Industrial Switching Power Adaptor
1. The specification of AC voltage used in Din-Rail Industrial Switching Power Adaptor is 110VAC/ 220VAC/ 380VAC power supply. Before power on, check whether the connected voltage is consistent with the input voltage of power supply.
2. Before the first power on, do not connect the load. First, check whether the output voltage of the power supply is consistent with the power supply of the connected equipment, so as not to damage the connected equipment.
3. The ground wire should be connected well before the power supply is used. The ground wire of this type of power supply should be marked in the figure.
4. The power supply should be placed in the center with good ventilation.
5. The output current of Din-Rail Industrial Switching Power Adaptor is definitely fixed; According to the rated standard current of the equipment supplied by the guide power supply or the multimeter to measure the uniform current value is sure. In the case of high ambient temperature, poor air activity and rational load, 20-30% extra current allowance should be prepared.
6.The input power of Din-Rail Industrial Switching Power Adaptor is determined: the input power of guide power supply depends on the rated marked power of the supplied equipment. If the rated power of the supplied equipment is unknown, the product value of the rated current and voltage of the supplied equipment can be used to obtain (current X voltage = power). When the user selects the power supply, it should be greater than 15-30% of the practical power and peak power.
7. Din-Rail Industrial Switching Power Adaptor output DC number is determined: guide power supply has a maximum of four conventional output. (S-single group, D-double group, T-three group, q-four group) according to the equipment provided for confirmation.
8. Din-Rail Industrial Switching Power Adaptor has over/under voltage, over current, overheat maintenance and fan cooling maintenance functions. Please stop the selection according to the practical application condition, in order to strengthen the stability and reliability of the system engineering.